Various maintenance of various incubators
The first incubator digital biochemical incubator maintenance and maintenance: 1. Observe the temperature of the incubator daily to meet the requirements. If you find an abnormal situation, please ask a professional to repair it. 2. When the lighting in the box is abnormal, it is necessary to replace the lighting fixtures in time. 3. Check if the heating furnace wire (compressor) is damaged when the heating (cooling) is abnormal, and repair it in time after damage. 4. Clean the outside of the incubator in time to keep it clean and free of dust. Thoroughly clean the incubator liner once a week with sterile water. Replace different types of disinfectant water every quarter to avoid the emergence of resistant strains. 5. A performance verification of this equipment should be performed annually. 6. Before using the equipment, carefully check whether the power supply voltage matches the requirements of the instrument. 7. When the device is not in use, set each control switch to a non-working state and cut off the power. Maintenance and maintenance of the second incubator digital light incubator: 1. The incubator housing should be reliably grounded. 2. The incubator should be placed in a cool, dry, well-ventilated place away from heat and sunlight. Place it smoothly to prevent noise from occurring. 3. In order to ensure the effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 100mm, the side of the box should have a gap of 50mm, and the top of the box should have at least 300mm space. 4. When the incubator is transported, repaired and maintained, it should avoid collision, shaking and shaking, and the maximum inclination is less than 45 degrees. 5. The instrument suddenly does not work. Please check if the fuse tube (after the box) is burnt out and check the power supply. 6. When the incubator is working in refrigeration, it is not advisable to make the difference between the temperature inside the box and the ambient temperature greater than 25 degrees. 7. The illumination time can be programmed and controlled by the “programmable time controllerâ€. Please refer to the "Programmable Time Controller" instructions for programming methods. Maintenance of the third incubator shaker incubator: 1. During the continuous operation, the instrument should do a regular inspection every three months; check the fuses, control components and fastening screws, and whether there are water droplets, dirt and other falling into the motor and control components. 2. The bearing of the transmission part has been filled with the proper amount of grease before leaving the factory. During the continuous operation, the instrument should be filled with grease once every six months, and the filling amount accounts for 1/3 of the bearing space. 3. The compressor should avoid continuous starting. 4, the instrument is used frequently, natural wear is a normal phenomenon. After one year of use, if the motor or compressor is found to have abnormal noise; the transmission part bearing is worn, the belt is loose or cracked, and the electronic control component fails, the company will continue to provide quality service and assist in handling it. service line. Bone Glue,Bone Glue Gelatin,Animal Bone Glue,Industrial Grade Bone Glue Hebei Haodong Biological Technology Co.,Ltd. , https://www.hdgelatin.com