Several common faults of the pump

When the pump is running, it often encounters problems. The following are some of the six common causes of failure:

First, the supporting power motor is overheated

There are four reasons. First, the reason for the power supply: the voltage is high or low. Under certain load, if the voltage fluctuation range should be +10% to -5% of the rated value, the motor will overheat; the power supply three-phase voltage is asymmetrical, the power supply If the three-phase electric voltage phase imbalance is more than 5%, the winding will be overheated; the phase loss operation, the experience shows that the agricultural motor is burned more than 85% due to the lack of phase operation, and the motor should be installed with phase loss protection device. The second is the reason for the pump, the power is not matched, the small horse-drawn carriage, the motor is overloaded for a long time, the motor temperature is too high; the motor that starts too frequently, the quota is short or intermittent work continuously. The number of starts should be limited, the thermal protection should be selected correctly, and the scale should be used according to the calibration on the motor. The third is the cause of the motor itself; the error is revealed, the △ shape is mistakenly connected to the Y shape, so that the temperature of the motor rises rapidly; the stator winding has a phase-to-phase short circuit, an inter-turn short circuit or a local grounding. When the light is light, the motor is locally overheated, and when it is severe, the insulation is burnt. Broken; squirrel cage rotor broken or defective, the motor runs for 1 to 2 hours, the core temperature rises rapidly; through the system failure, should check whether the fan is damaged, the rotation direction is correct, the vent hole is blocked; bearing wear, rotor eccentricity The broom makes the iron core of the stator and rotor rub the metal to make a sound, and the temperature of the iron core rises rapidly. When the motor is serious, the motor smokes and even the coil burns. The fourth is the working environment; the motor windings are damp or dust, oil, etc. are attached to the windings, resulting in lower insulation. The insulation resistance of the motor should be measured and cleaned and dried; the ambient temperature is too high. When the ambient temperature exceeds 35 ° C, the inlet air temperature is high, the temperature of the motor will be too high, and efforts should be made to improve the working environment, such as tower awning. Note: If there is a malfunction due to electrical reasons, the electrician who has obtained the professional qualification certificate should be repaired. Those who know nothing about it should not be blindly repaired to prevent personal injury.

Second, insufficient traffic

This is because: the power speed is not matched or the belt slips, so the speed is low; the axial pump blade installation angle is too small; the head is insufficient, the pipeline is too long or the pipeline has a right angle bend; the suction stroke is high; the bottom valve, the pipeline And partial impeller or impeller defect; the water leakage of the outlet pipe is serious. Remedy; restore the set speed, remove the belt grease, adjust the blade angle, reduce the pump installation position, shorten the pipeline or change the bending of the pipeline; seal the pump leak, press the seasoning; remove the blockage, replace the impeller; Replace the leak ring and block the leak.

Third, the pump heat

Cause: The bearing is damaged; the gap between the rolling bearing or the bracket cover is too small; the pump shaft is bent or the two shafts are not concentric; the tape is too tight; the oil or oil is not good; the balance hole on the impeller is blocked, the impeller is out of balance, and the direction is increased. The thrust on one side. Remedy; replace the bearing; remove the rear cover, install a gasket between the bracket and the bearing housing; investigate the pump shaft or adjust the concentricity of the two shafts; properly adjust the tightness of the tape; add clean butter, butter accounts for the bearing About 60% of the gap; clearly balance the blockage in the hole.

Fourth, can not start the situation

First check the power supply: whether the connector is secure; whether the switch is tight; whether the fuse is blown; whether the three-phase power supply is equal. If there is an open circuit, poor contact, blown fuse, or lack of phase, the cause should be identified and repaired in time. Secondly, it is checked whether it is a mechanical failure of the pump . The common reasons are: the packing is too tight or the impeller and the pump body are stuck by the debris; the pump shaft, the bearing, the leakage ring rust, the pump shaft is severely bent. Remedy; loosen the packing, dredge the gutter; disassemble the pump body to clear debris, remove rust; remove the pump shaft to correct or replace the new pump shaft.

Five, can not absorb water

The reason is that there is air or water in the pump body, or the bottom valve is not closed, the water pump is not full, the vacuum pump packing is seriously leaked, and the gate valve or the door is not closed. Exclusion method; first press the water up, then fill the pump body with water, then turn it on. Colleagues check whether the check valve is tight, and whether the pipeline or joint is leaking. If air leakage is found, apply lubricant or blend paint at the joint after tightening, and tighten the screw. Check the oil seal ring of the pump shaft. If the wear is serious, replace the new one. The pipeline is leaking or leaking. The nut may not be tightened when it is installed. If the leakage is not serious, apply cement in the place where air leaks or leaks, or apply cement slurry with asphalt oil. Temporary repairs can be applied to wet mud or soft soap. If there is water leakage at the joint, the nut can be tightened with a wrench. If the water leakage is serious, it must be disassembled and replaced with a cracked pipe. Reduce the lift and press the nozzle of the pump into the water 0.5m.

Sixth, severe vibration

There are several reasons for the following: unbalanced electric rotor; poor coupling of the coupling; wear and bending of the bearing; loose and broken parts of the rotating part; Adjustment, repair, reinforcement, straightening, etc. can be taken separately.

Desktop Type Dental Milling Machine

The chair side CAD / CAM repair system has obvious advantages in aesthetic effect, operation time, patient participation and operation convenience. Discussion: traditional repair method: after the model is transferred, it will be sent to the technician's room for processing and making the final prosthesis. About one week, the final prosthesis will be tried on, grinded and bonded. The prosthesis was made in the technician's room. The patients need to accept the aesthetic effect of the prosthesis passively without any sense of participation. The implant repair method of chair side CAD / CAM system: obtain computer three-dimensional model by blue light scanning method, design and make personalized abutment and all ceramic restoration on computer, dye, glaze and bond after trial wearing, the whole restoration is made by chair side, patients can directly participate in the restoration design, and feel more involved. Conclusion: in the implant area of the anterior teeth, compared with the traditional implant repair method, the chair side repair system can get more satisfactory results, which is worthy of clinical application and promotion.