Common glitch handling methods in the laboratory

Common glitch treatment methods in the laboratory<br> There are often some unexpected "small troubles" in the laboratory. For example, the stopper can not be opened, the dirt on the instrument is difficult to remove, and the emulsification occurs during liquid separation. Wait. If you can take the appropriate methods or techniques to deal with them, these troubles will be solved.
1. Open the fixed glass grinding port <br> When the grinding part of the glass instrument cannot be opened due to sticking, the following methods can be used.
(1) Tap the wood to gently tap the side of the grinding part to loosen it due to vibration. For the fixed reagent bottle, the grinding plug of the separatory funnel, etc., the plug and the mouth of the instrument can be stuck at the corner of the test bench or the wooden table, and then the wood is lightly inclined at an angle of about 70° to the axis of the instrument. The tapping is performed while the instrument is rotated intermittently, and the operation is repeated several times, and the grinding which is not seriously fixed can be generally opened.
(2) Heating some fixed grinding mouth, inconvenient to knock or knock is invalid, the outer layer of the fixing part can be heated to be thermally expanded and detached from the inner layer. For example, use a hot damp cloth to "hot pack" the sticky place, bake the ground with a hair dryer or a moving flame, and so on.
(3) Infiltration Some grinding joints are firmly adhered due to drug erosion, or are valuable instruments with complicated structure. It is not suitable for tapping and heating. It can be opened by soaking in water or dilute hydrochloric acid for several hours. If the instrument is used urgently, an organic solvent with strong penetrability (such as benzene, ethyl acetate, petroleum ether and sodium dioctyl sulfosuccinate) may be added to the gap between the grinding ports to make it infiltrated into the stick. The parts that are fixed and thus detached from each other.
2. Open the screw cap that is fastened <br> When the screw cap cannot be opened, use a hair dryer or a small flame to bake the bottle cap around it, so that it can be heated and expanded, and then used to wrap the cap and force it. Unscrew.
If the bottle is filled with unheatable or flammable materials, take a strong rope, one end on a fixed object (such as the door and window handle), then turn the rope clockwise around the bottle cap, then hand in hand At the other end of the rope, holding the bottle in one hand and pushing it forward can open the cap.
3. Remove the thermometer that is glued by the rubber plug <br> When the thermometer or glass tube is stuck with the rubber plug or hose and it is difficult to remove it, insert the thermometer (or glass tube) and the rubber plug with the tip of the small screwdriver or knife. Between the (or hose), make a gap, and then drop a few drops of water, and then operate along the thermometer (or glass tube) to expand, while gradually deepening, will be quickly removed. You can also use a drill that just fits into the thermometer (or glass tube), put a little glycerin or water on it, put it in from one end of the thermometer, gently push it while pushing it, and when it is difficult to turn it, pull it out and put it on it. Lubricant, continue to rotate, and after repeated several times, the thermometer (or glass tube) can be taken out.
4. Remove special dirt on the instrument <br> When reflowing or concentrating the solution, crystals are often deposited on the inner wall of the flask above the liquid surface, and the adhesion is firm, not only can not continue to participate in the reaction, and sometimes due to poor thermal stability And gradually decomposes discoloration. In this case, the flask can be gently shaken, and the internal solution is impregnated and crystallized to dissolve. If the apparatus is not restricted in activity and the flask cannot be shaken, a cold wet cloth may be applied to the upper portion of the flask to dissolve the precipitated crystals when the solvent condenses down the wall.
5. Dissolving crystals precipitated on the inner wall of the flask <br> When reflowing or concentrating the solution, crystals are often deposited on the inner wall of the flask above the liquid surface, and the adhesion is firm, not only cannot continue to participate in the reaction, but sometimes it is thermally stable. Poorly discolored and gradually disintegrated. In this case, the flask can be gently shaken, and the internal solution is impregnated and crystallized to dissolve. If the apparatus is not restricted in activity and the flask cannot be shaken, a cold wet cloth may be applied to the upper portion of the flask to dissolve the precipitated crystals when the solvent condenses down the wall.
6. Packing up the spilled mercury <br> Commonly used in the laboratory is a mercury- filled pressure gauge and a mercury thermometer. If the operation is improper or the thermometer is damaged, a “spraying accident” will occur. Mercury vapor is extremely harmful to the human body, and it is necessary to promptly and thoroughly clean up the spilled mercury, and it must not be allowed to be lost. There are many cleaning methods, which can be selected according to different situations.
(1) Absorb a small amount of mercury, and use a common dropper to suck up the mercury beads one by one and collect them in a container. If the amount of mercury is large or spilled in the gap of the groove, the suction filter bottle can be connected to a 75° glass elbow through a rubber plug, and a “decompression aspirator” can be made to pass the mercury particle through the negative pressure. The glass tube is sucked into the filter bottle. The connection between the suction filter bottle and the pressure relief pump can be slightly longer to avoid drawing mercury into the pump.
(2) Adhesion of mercury spilled on the table top (or the ground). If it has been dispersed into fine particles, it can be adhered with tape paper, then immersed in water and brushed into the container with a brush. This method is simple and easy to perform.
(3) The melting point of frozen mercury is -38.87 °C. If the sprinkled mercury is covered with an appropriate amount of dry ice-acetone mixture, the mercury will be frozen into a solid and lose fluidity within a few seconds, which is easier to clean.
(4) Conversion For the trace mercury that is scattered in the corner and difficult to be collected by the above method, the sulfur powder can be used to cover the area where the mercury particles are lost, and the mercury and sulfur are combined to form mercury sulfide with less toxicity, and then removed.
7. Elimination of emulsification <br> When using a separatory funnel for extraction and washing operations, especially when the organic matter is washed with an alkali solution, it is often difficult to separate due to emulsification without delamination. If the degree of emulsification is not serious, the separatory funnel can be slowly rotated in the horizontal direction and then left to stand for a while to eliminate the foam at the interface and promote delamination. If it is still not layered, add a proper amount of water, then shake it horizontally or place it overnight to separate the clear interface.
If the density of the solvent is close to that of water, it is easy to emulsify with water during extraction or washing. At this point, an appropriate amount of diethyl ether can be added thereto to lower the density of the organic phase, thereby facilitating delamination.
For an emulsion formed by a slightly soluble ester of water and water, it can be stratified by adding a small amount of an inorganic salt such as sodium chloride or ammonium sulfate.
8. Rapid drying instrument <br> When the experiment is urgently needed to use the dry instrument, and it is too late to dry by the conventional method, the inner wall of the instrument can be washed twice with a small amount of absolute ethanol, and then rinsed once with a small amount of acetone to remove residual ethanol. Then, use a hair dryer to blow for a while to achieve the drying effect.
9. Stabilizing the flask in the water bath <br> When cooling the material in the conical flask with cold water or ice bath, the flask will float due to the small amount of material and the buoyancy of the bath, which will affect the cooling effect, and sometimes the flask will occur. Incline the accident of pouring into the bath. If a circle of moderate length is used to make a circle smaller than the bottom diameter of the conical flask, the flask is placed in the flask and the flask is immersed in the bath. If the container used is a beaker, the circle can be placed over the beaker and the wire is hung on the mouth of the beaker to stabilize it and achieve sufficient cooling.
10. Making a simple constant temperature cooling bath <br> When some experiments require the temperature of the constant temperature bath to be kept below room temperature, cooling with cold water or ice bath often does not achieve satisfactory results. At this time, you can make a simple constant temperature cooling tank: use a larger carton (reagent or instrument box) as the outer tank, put the thermostatic bath into the carton as the inner tank, and put a proper amount of dry ice between the inner and outer tanks. Then use foam plastic as insulation material to fill the gap and cover the upper part. The amount of dry ice can be adjusted according to the temperature and time required for the experiment. This cooling tank is easy to manufacture and has a good heat preservation effect.
When a special stain is adhered to a glass instrument and it is difficult to remove it by a general washing method, the nature of the soil should be distinguished first and then treated in a targeted manner.
For acidic soils that are insoluble in water, such as organic acids and phenolic deposits, they can be washed with lye and then washed; for alkaline soils that are insoluble in water, such as metal oxides and scales, they can be washed with hydrochloric acid and then cleaned; Potassium permanganate deposit can be washed with sodium sulfite or oxalic acid solution; manganese dioxide deposit can be dissolved by concentrated hydrochloric acid; when iodine is used, it can be soaked with potassium iodide solution; silver nitrate stain can be washed with sodium thiosulfate solution and then washed; The silver (or copper) adhered after the reaction of the silver mirror (or copper mirror) can be dissolved by adding dilute nitric acid to the slight heat; the tar or resinous dirt can be immersed in an organic solvent such as benzene or ester, and then washed by an ordinary method. . For glass equipment that cannot be cleaned by the above method, the edge of the dirt can be wetted with dilute hydrofluoric acid, and the dirt will fall off along with the thin layer of the etched glass, and then washed with water. Although the glass is corroded, the damage is small and generally does not affect the continued use.
Well, for the lab's common glitch handling methods, Xiaobian is here today. What else do you need to add? Come and contact me!
Welcome to Beijing hundred O'Brien Wei Biotechnology Co., Ltd, the site belongs to Beijing hundred O'Brien Wei Biotechnology Co., Ltd., the unit now provides microbial strains and cell and other related products inquiries, advice, ordering, after-sales service! With a number of domestic and foreign research and development units, biomedicine, third-party testing institutions, research institutes have a good and stable long-term cooperative relationship! Welcome customers to inquire!