Laboratory Full-Auto Biochemistry Analyzer (AM-220)

Model NO.: AM-220
Auto: Full Auto
Trademark: AMISMED
Specification: CE
Origin: China
HS Code: 90278099
Model NO.: AM-220
Auto: Full Auto
Trademark: AMISMED
Specification: CE
Origin: China
HS Code: 90278099
Full-auto Biochemistry Analyzer AM-220 Laboratory

Laboratory Full-Auto Biochemistry Analyzer (AM-220)




280T/H (Singel/Dual Reagent) 24 hrs refrigeration(Reagent tray)
45 reagent positions, 60 sample positions, 120 reaction positions
8-step auto washing system
Precise & Reliable Sample/Reagent Filling System
Liquid level detection and volume-tracing technology: Precision filling to lessen the surface carryover
Three-dimensional probe protection technology: Collision protection, reset automatically

Bubble removing of fluid pipe technology: Vacuum degassing device effectively removes the air dissolved in fluid pipe and fill the sample and reagent precisely
Needle-plug detection technology: Intellisense whether the needle is blocked
High performance separate mixer design: Solve the problem of easy-to-condensate samples completely
Detect the sample/reagent residual volume automatically
Convenient & Effective Automatic Cleaning System

Clean the reaction cups by 8 steps and monitor the process automatically.
Pre-heating cleaning solution enhances the cleaning effect
Stable Reaction Cup Unit
Adopting air-bath technology makes the reaction cup evenly heated
Linear frequency temperature control, and temperature fluctuats within 0.1 degrees.
Thermostat device making rapid heating to meet the need of out-patient & emergency
Integrative Intelletrualized Sample needle&Reagent needle
Single needle liquid level detection design
Volume-tracking technology makes less cross-contamination among needle, sample and reagent.

Reliable Optical System
Back-spectro technology to avoid light scattering
Point source technology to achieve ultra trace analysis in order to save more reagents
Optical fiiber to transmit the signal with strong anti-jamming capability
Silicon photoelectric diode synchronous detector to ensure speed analysis
Software Platform meets customer's special requirements
Real-time whole-process reaction curve Report calculation items automatically
Self-define normal value range Print levey-jennings

Technical feature
Performance
Test Speed: 280tests/h
Test Function: Full-auto, discrete, Random access, 45 programmes simultaneously, 24hrs boot, STAT priority,
Test scope: Serum, plasma, urine
Test method: End-point, two-point, kinetic, Single/dual reagent, Single/double wavelength, linear, non-linear calibration
Items Setting: Open system, supporting the imported reagent and domestic reagent, providing arbitrary combination and optional programmes
Test Setting, single, double, combination, batch, contrast setting

Sample system
Sample tray: 60 positions for primary tubes or secondary cups
Sample volume: 2-50μ L, 0.1μ L by step, automatic sampling and deduction of sample blank during test
Sample needle: Multifunctional, liquid-detection & anti-collision protection function
Reagent System
Reagent refrigeration: 4-10° C, 24 hrs non-stop refrigeration
Reagent volume: 20-450μ L, 0.1μ L by step, fixed when set the items
Reagent needle: : Multifunctional, liquid-detection & anti-collision protection function

Reaction Center
Reaction Tray: Disc type, 6 linked cuvettes, 120 reaction positions
Reaction Volume: Mini 150μ L, Max 500μ L
Reaction Temperature: Thermostaic cuvette, 37° C, real-time display
Mixing System: Separate mixer mix the sample and reagent completly
Optical System
Optical Source: Tungsten-halogen lamp, 12V/35W, 2000hrs service time
Wavelength: 8 wavelengths selectable among 340-800nm
Absorbance: 0-4.0ABS
Resolution: 0.0001ABS
Working conditions:
Power: AC220V± 10%, 50Hz, 500w
Ambient temp: 15-30 ° C

Laboratory Full-Auto Biochemistry Analyzer (AM-220) Full-auto Biochemistry Analyzer AM-220 Laboratory

Laboratory Full-Auto Biochemistry Analyzer (AM-220)




280T/H (Singel/Dual Reagent) 24 hrs refrigeration(Reagent tray)
45 reagent positions, 60 sample positions, 120 reaction positions
8-step auto washing system
Precise & Reliable Sample/Reagent Filling System
Liquid level detection and volume-tracing technology: Precision filling to lessen the surface carryover
Three-dimensional probe protection technology: Collision protection, reset automatically

Bubble removing of fluid pipe technology: Vacuum degassing device effectively removes the air dissolved in fluid pipe and fill the sample and reagent precisely
Needle-plug detection technology: Intellisense whether the needle is blocked
High performance separate mixer design: Solve the problem of easy-to-condensate samples completely
Detect the sample/reagent residual volume automatically
Convenient & Effective Automatic Cleaning System

Clean the reaction cups by 8 steps and monitor the process automatically.
Pre-heating cleaning solution enhances the cleaning effect
Stable Reaction Cup Unit
Adopting air-bath technology makes the reaction cup evenly heated
Linear frequency temperature control, and temperature fluctuats within 0.1 degrees.
Thermostat device making rapid heating to meet the need of out-patient & emergency
Integrative Intelletrualized Sample needle&Reagent needle
Single needle liquid level detection design
Volume-tracking technology makes less cross-contamination among needle, sample and reagent.

Reliable Optical System
Back-spectro technology to avoid light scattering
Point source technology to achieve ultra trace analysis in order to save more reagents
Optical fiiber to transmit the signal with strong anti-jamming capability
Silicon photoelectric diode synchronous detector to ensure speed analysis
Software Platform meets customer's special requirements
Real-time whole-process reaction curve Report calculation items automatically
Self-define normal value range Print levey-jennings

Technical feature
Performance
Test Speed: 280tests/h
Test Function: Full-auto, discrete, Random access, 45 programmes simultaneously, 24hrs boot, STAT priority,
Test scope: Serum, plasma, urine
Test method: End-point, two-point, kinetic, Single/dual reagent, Single/double wavelength, linear, non-linear calibration
Items Setting: Open system, supporting the imported reagent and domestic reagent, providing arbitrary combination and optional programmes
Test Setting, single, double, combination, batch, contrast setting

Sample system
Sample tray: 60 positions for primary tubes or secondary cups
Sample volume: 2-50μ L, 0.1μ L by step, automatic sampling and deduction of sample blank during test
Sample needle: Multifunctional, liquid-detection & anti-collision protection function
Reagent System
Reagent refrigeration: 4-10° C, 24 hrs non-stop refrigeration
Reagent volume: 20-450μ L, 0.1μ L by step, fixed when set the items
Reagent needle: : Multifunctional, liquid-detection & anti-collision protection function

Reaction Center
Reaction Tray: Disc type, 6 linked cuvettes, 120 reaction positions
Reaction Volume: Mini 150μ L, Max 500μ L
Reaction Temperature: Thermostaic cuvette, 37° C, real-time display
Mixing System: Separate mixer mix the sample and reagent completly
Optical System
Optical Source: Tungsten-halogen lamp, 12V/35W, 2000hrs service time
Wavelength: 8 wavelengths selectable among 340-800nm
Absorbance: 0-4.0ABS
Resolution: 0.0001ABS
Working conditions:
Power: AC220V± 10%, 50Hz, 500w
Ambient temp: 15-30 ° C

Laboratory Full-Auto Biochemistry Analyzer (AM-220)

Torch Shaped Wafer Ice Cream Cone

Torch Shaped Wafer Ice Cream Cone,Wafer Products In The Shape Of Torch,Wafer Cone Filled With Soft Ice,Flat Mouth Conical Wafer Products

Tianjin Yongkang Food Co., Ltd , https://www.yongkangfood.com