Classification of specifications of platinum-iridium thermocouples
Platinum rhodium thermocouples measure temperature and tolerance Thermocouple category Code Index number Maximum temperature measure temperature Allowable deviation Δt °C Platinum rhodium 30-platinum rhodium 6 WRR B 0~1800 0-1600 ±1.5°C or ±0.25%t Platinum rhodium 10-platinum WRP S 0~1600 0-1300 ±1.5°C or ±0.25%t Platinum rhodium thermocouple models and specifications Platinum rhodium thermocouple type Platinum rhodium thermocouple index Platinum rhodium thermocouple temperature range °C Platinum rhodium thermocouple protection tube material Thermal response time Platinum rhodium thermocouple specification d L x l WRP-130 S 0-1300 High aluminum < 150S Φ16 300x150 WRP-131 < 360S Φ25 WRQ-130 R 0-1300 < 150S Φ16 WRQ-131 < 360S Φ25 WRR-130 B 0-1600 Corundum tube < 150S Φ16 WRR-131 < 360S Φ25 The principle of temperature measurement of platinum-iridium thermocouple: when two different kinds of metal conductors are respectively connected together to form a closed loop, when the two nodes are distorted, current flows in the conductor loop, and a thermoelectric potential is generated. This phenomenon is called the thermoelectric effect. Use this effect. As long as you know the junction temperature at one end, you can side out the temperature of the other end node. The fixed temperature node To is called the reference point (cold end), constant at a certain standard. Temperature; the side temperature node is called the side temperature point (hot end). Because the platinum-iridium thermocouple is used as the temperature measurement sensor in the side temperature field, it is usually used together with the temperature transmitter, regulator and display instrument to form the process control. System, platinum-rhodium thermocouples are used to directly measure or control the temperature of fluids/steam and gas media and solid surfaces in the range of 0-1800 °C in various production processes.
WRP2-130
350x200
400x250
450x300
550x400
650x500
900x750
1150x1000
1650x1500
2150x2000
WRP2-131
WRQ2-130
WRQ2-131
WRR2-130
WRR2-131
Zhongneng Instrument Experts said that the characteristics of platinum-iridium thermocouples are remarkable: they have the highest accuracy, the best stability, wide temperature range, long service life and high temperature limit. They can be applied to oxidizing and inert atmospheres. It can be used in vacuum for a short time, but it is not suitable for reducing atmosphere or containing metal or non-metal vapor atmosphere. Therefore, platinum-ruthenium thermocouple can be widely used in powder metallurgy, sintering bright furnace, vacuum furnace, smelting furnace, glass, refining. Temperature measurement in steel furnaces and ceramics and industrial salt bath furnaces.